Heat Resistant, Multi-Core Cables - Pektas Cable
FLEXIBLE CABLES

h03v2v2-f

Low voltage household appliances under less mechanical compulsion in high temperature environments.
Max. operating temperature
90 °C
Max. short circuit temperature
150 °C
AC test voltage
2kV
Min. bending radius
D≤12 is 5 x D, D>12 is 6 x D
Rated voltage Uo/U
300/300 V, 300/500 V
Flame propagation test on single cable
EN 60332-1

Construction

  • 1- Fine-stranded copper (Class 5)
  • 2- High temperature resistant polyvinyl chloride
  • 3- High temperature resistant polyvinyl chloride

Applications

Low voltage household appliances under less mechanical compulsion in high temperature environments.

Technical Data - H03V2V2-F (300/300 V) / 209Y & H05V2V2-F (300/500 V) / 309Y / Cu/HR-PVC/HR-PVC

Nominal Cross Section mm²Overall Diameter mmNet Weight kg/kmConductor DC Resistance at (20°C) max. ohm/kmCurrent Carrying Capacity in Air (A)
2x0.505.03739.03
2x0.755.54626.06
3x0.505.04339.03
3x0.755.55426.06
4x0.506.05439.03
4x0.756.57026.06
2x16.66519.510
2x1.57.28713.316
2x2.58.71317.9825
3x0.756.76826.06
3x16.77719.510
3x1.58.110613.316
3x2.59.81647.9825
3x411.42324.9532
4x0.757.18326.06
4x18.310019.510
4x1.59.114213.316
4x2.510.12017.9825
5x0.758.110226.06
5x18.812419.510
5x1.510.217513.316
5x2.512.42547.9825
5x413.93554.9532